Commercial reverse osmosis point-of-use systems in Egypt failed to purify tap water

Mahmoud Gad,Mohamed A. Marouf, Amr Abogbal,Anyi Hu, N. Noura

JOURNAL OF WATER AND HEALTH(2024)

引用 0|浏览1
暂无评分
摘要
This study addresses the heightened global reliance on point-of-use (PoU) systems driven by water quality concerns, ageing infrastructure, and urbanization. While widely used in Egypt, there is a lack of comprehensive evaluation of these systems. We assessed 10 reverse osmosis point-of-use systems, examining physicochemical, bacteriological, and protozoological aspects of tap water (inlets) and filtered water (outlets), adhering to standard methods for the examination of water and wastewater. Results showed significant reductions in total dissolved solids across most systems, with a decrease from 210 +/- 23.6 mg/L in tap water to 21 +/- 2.8 mg/L in filtered water for PoU-10. Ammonia nitrogen levels in tap water decreased from 0.05 +/- 0.04 to 2.28 +/- 1.47 mg/L to 0.02 +/- 0.04 to 0.69 +/- 0.64 mg/L in filtered water. Despite this, bacterial indicators showed no significant changes, with some systems even increasing coliform levels. Protozoological analysis identified prevalent Acanthamoeba (42.5%), less frequent Naegleria (2.5%), Vermamoeba vermiformis (5%), and potentially pathogenic Acanthamoeba genotypes. Elevated bacterial indicators in filtered water of point-of-use systems, combined with essential mineral removal, indicate non-compliance with water quality standards, posing a public health concern. Further research on the long-term health implications of these filtration systems is essential.
更多
查看译文
关键词
bacteria,Egypt,physicochemical parameters,protozoa,reverse osmosis point-of-use systems,water quality
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要