Model comparison and effect of flow and accessories on the pressure drop of the unit ff-df-270/el of Universidad de Cartagena

Angel Villabona-Ortiz, Angel Gonzalez-Delgado, Candelaria-Tejada-Tovar

INGENIERIA Y COMPETITIVIDAD(2023)

引用 0|浏览0
暂无评分
摘要
The effect of flow variation on the theoretical calculation of pressure drop in pipes with fittings in the unit FF-DF-270/EL of the Universidad de Cartagena was studied, determining the coefficient of minor losses (K-f) caused by 45 degrees and 90 degrees elbows, and three types of valves, using water as the process fluid. The flow rate (Q) was varied, using a valve, between 24, 20, 16, 12 L/min. Darcy's and Bernoulli's theorem methods were used to evaluate friction losses. Were found minimum error percentages of 0.04% and maximum 8.16%; loss coefficients adjusted by minimum squares were obtained with R-2 of 0.999, comparing these K-f with the values reported in the plant manual and different authors. It was shown experimentally that the loss coefficient depends on each fitting, allowing the calculation of the theoretical pressure drop and comparing it with the experimental pressure drop, demonstrating that as the flow increases, an increase in pressure drop is generated. With the methodology applied in this research, the aim is to optimize pressure drop tests with fittings, and identify the characteristics of the pipe to obtain an optimum lower loss coefficient value.
更多
查看译文
关键词
Pressure drop,Model comparison,Loss coefficient,Friction
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要