It was not possible to detect BRAF V600E mutation in circulating cell-free DNA from patients with ameloblastoma: A diagnostic accuracy study

Allan Vinicius Martins-de-Barros,Fabio Andrey da Costa Araujo,Ana Maria Ipolito Barros, Elenisa Glaucia Ferreira dos Santos, Adauto Gomes Barbosa Neto, Helker Albuquerque Macedo da Silva, Elker Lene Santos de Lima,Maria Tereza Cartaxo Muniz, Riedel Frota Sa Nogueira Neves, Romulo Oliveira de Hollanda Valente,Emanuel Dias Silva,Marianne de Vasconcelos Carvalho

JOURNAL OF ORAL PATHOLOGY & MEDICINE(2024)

引用 0|浏览0
暂无评分
摘要
Background :The objective of this study is to evaluate the diagnostic accuracy of plasma-based liquid biopsy for the detection of the BRAF V600E mutation in circulating cell-free DNA from patients with ameloblastoma. Methods :This is a prospective diagnostic accuracy study conducted based on the Standards for Reporting Diagnostic Accuracy recommendations. The index test was the plasma-based liquid biopsy, whereas the reference standard was the conventional tissue biopsy. The target condition was the detection of BRAF V600E mutation. The study population consisted of individuals with ameloblastoma recruited from three tertiary hospitals from Brazil. A negative control group composed of three individuals with confirmed wild-type BRAF lesions were included. The participants underwent plasma circulating cell-free DNA and tumor tissue DNA isolation, and both were submitted to using competitive allele-specific TaqMan (TM) real-time polymerase chain reaction technology mutation detection assays. Sensitivity and specificity measures and positive and negative predictive values were calculated. Results :Twelve patients with conventional ameloblastoma were included. BRAF V600E mutation was detected in 11/12 (91.66%) ameloblastoma tissue samples. However, the mutation was not detected in any of the plasma-based liquid biopsy circulating cell-free DNA samples in both ameloblastomas and negative control group. The sensitivity and specificity of plasma-based liquid biopsy for the detection of the BRAF V600E mutation in circulating cell-free DNA was 0.0 and 1.0, respectively. The agreement between index test and reference standard results was 26.66%. Conclusion :Plasma-based liquid biopsy does not seem to be an accurate method for the detection of the BRAF V600E mutation in circulating circulating cell-free DNA from patients with ameloblastoma, regardless of tumor size, anatomic location, recurrence status, and other clinicopathological features.
更多
查看译文
关键词
ameloblastoma,BRAF V600E,cell-free nucleic acids,liquid biopsy,proto-oncogene proteins B-raf
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要