Application-Driven Data Acquisition for Condition Monitoring of Power Semiconductors in Traction Inverter Applications

IEEE Transactions on Transportation Electrification(2023)

引用 0|浏览0
暂无评分
摘要
Condition monitoring has proven to be an effective means of enhancing the reliability of power semiconductors. This paper proposes an innovative and practical data acquisition scheme that can serve various condition monitoring purposes for power semiconductors in traction inverter applications. It is achieved through the DC-link discharging operation mode of the traction inverter after the system is shut down, minimizing the new risks introduced by condition monitoring into system operation, which is critical to the safety of traction applications. Moreover, due to the extremely low dynamics in the discharging operation mode, the sampling requirements for the health indicators and operating conditions of power semiconductors are greatly reduced, and the measurement disturbances from parasitic parameters are eliminated. The proposed method is promising for electric vehicle (EV) applications as the required operation condition is an inherently programmed and frequent mode. Compared to conventional online data acquisition schemes, it outperforms in complexity, accuracy, safety, and practicality. The proof-of-concept experiments based on a three-phase inverter prototype verify the effectiveness of the proposed method.
更多
查看译文
关键词
Condition monitoring,traction inverter,electric vehicle,power semiconductor,data acquisition