Validating the usefulness of Sudoscan in ATTRv: a single centre experience

Elena Moreno-Moraleda, Juan González-Moreno,Eugenia Cisneros-Barroso, María Antonia Ribot-Sansó,Tomás Ripoll-Vera,Cristina Descals, Mercedes Uson,Joan Carles Montalà,Antoni Figuerola, Adrián Rodríguez,Inés Losada

Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology(2024)

引用 0|浏览1
暂无评分
摘要
Variant transthyretin amyloidosis (ATTRv) can cause sensorimotor and autonomic neuropathy. Objective quantification of sudomotor function may be essential for early diagnosis and early initiation of treatment. The aim of this study is to evaluate the diagnostic value of the Sudoscan® in ATTRv. Electrochemical skin conductance (ESC) was measured in V30M ATTRv patients, asymtomatic V30M carriers and healthy controls. Comparisons between the three groups were made using the Kruskal-Wallis test, and ROC curves were used to estimate the discriminatory power of ESC values between groups. ESC was measured in 52 ATTRv patients, 107 asymptomatic carriers and 40 healthy controls. ESC was significantly lower in ATTRv patients compared to asymptomatic carriers and healthy controls in both feet and hands; median values are as follows: 40 µS, 78 µS and 81 µS, respectively (p < 0.001), and 53 µS, 69 µS and 74 µS, respectively (p < 0.001). ESC in feet < 70.5 µS had a sensitivity of 89.7
更多
查看译文
关键词
Autonomic dysfunction,Early diagnosis,Electrochemical skin conductance,Rare disease,Variant transthyretin amyloidosis