Experimental Study on Radius Cut RBS-CFT Connections with Bidirectional Bolts Under Cyclic Loadings

Subhra Paul,Sajal K. Deb

Lecture notes in civil engineering(2023)

引用 0|浏览0
暂无评分
摘要
This paper presents experimental investigation on the evaluation of performance of radius cut steel reduced beam section (RBS) and on its role in improving overall behavior of RBS-CFT connections subjected to cyclic load. The radius cut RBS was designed as per steps proposed by Engelharth et al. Behavior of radius cut RBS and concrete-filled tube (CFT) connections with bidirectional bolts were examined. An experimental study was performed to find the performance of radius cut RBS under cyclic loading. It exhibited stable hysteretic behavior, and the RBS-CFT connection is found to be semirigid in nature. The strain data showed that the panel zone remained elastic always during the test. It reached a rotational capacity of 0.04 radians without any damage in the joint panel region and thereby meets the seismic provisions of the AISC 2010 for a special composite moment-resisting frame.
更多
查看译文
关键词
bidirectional bolts,rbs-cft
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要