Chitty Sa, Sarah Mobbs,Brian S. Rifkin, Stogner Sw,Michael Lewis,Jaime Betancourt,Jeffrey DellaVolpe, Fadi Abouzahr, Wilhelm Am,Harold M. Szerlip, Gaeta Rm, Ian Rivera, Oliver Jd, Olson Sw,Subrata Debnath, Barnett Sp,Amay Parikh, Walter Rj, Nguyen Mt, Brittany Sullivan, Alcover Kc, Stewart Ij, Pratt Kp,Kumar Sharma,Chung Kk

medRxiv (Cold Spring Harbor Laboratory)(2021)

引用 0|浏览1
暂无评分
摘要
Objective The Seraph ® 100 Microbind Affinity Blood Filter ® (Seraph 100) is an extracorporeal medical countermeasure that can remove many pathogens from blood, including the SARS-CoV-2 virus. The aim of this study was to evaluate safety and efficacy of Seraph 100 treatment for severe coronavirus disease 2019 (COVID-19). Design Multicenter retrospective observational cohort study. Setting Intensive care units across four of thirteen participating sites who have completed data extraction. Patients Critically ill COVID-19 patients treated with Seraph 100 under an Emergency Use Authorization (n=53) and historical control patients who met criteria for treatment (n=46). Intervention Extracorporeal treatment with the Seraph 100 filter. Measurements and Main Results At baseline, the median age was 61 years, 72.7% were male, and 59.6% required mechanical ventilation. The groups were matched in terms of sex, race/ethnicity, body mass index, APACHE II score, need for mechanical ventilation, and other COVID-19 treatments. However, patients in the Seraph 100 group were younger with a median age of 61 years (IQR 42-65) compared to controls who had a median age of 64 (IQR 56-68, p=0.036). The Seraph 100 group also had a lower median Charlson comorbidity index (2, IQR 0-3) compared to control patients (3, IQR 2-4, p=0.006). Mortality was lower in the Seraph 100 treated group compared to the historical controls (37.7% vs 67.4%, respectively, p=0.003). Multivariable logistic regression analysis yielded an odds ratio of 0.27 (95% confidence interval 0.09-0.79, p=0.016). Of the 53 patients treated with Seraph 100, only 1 patient experienced a serious adverse event (transient hypotension at the start of the treatment which required a brief period of vasopressor support). Conclusions These data suggest that broad spectrum, pathogen agnostic, extracorporeal blood purification technologies can be safely and effectively deployed to meet new pathogen threats as an adjunct to standard treatments while awaiting the development of directed pharmacologic therapies and/or vaccines.
更多
查看译文
关键词
microbind affinity blood filter,blood purification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要