32.1 A Behind-The-Ear Patch-Type Mental Healthcare Integrated Interface with 275-Fold Input Impedance Boosting and Adaptive Multimodal Compensation Capabilities

2023 IEEE International Solid-State Circuits Conference (ISSCC)(2023)

引用 1|浏览3
暂无评分
摘要
Conventional brain activity monitoring devices including head bands and scalp caps are still not appropriate for daily-life monitoring applications because of their wearing discomfort and electrode-related artifacts. A proposed behind-the-ear (BTE) device, where motion artifacts are significantly reduced, would be a promising candidate for continuous mental healthcare platforms. This proposed BTE-based measurement allows multimodal bio-signals such as electroencephalogram (EEG), electrocardiogram (ECG), photoplethysmogram (PPG), and galvanic skin response (GSR), whereas most conventional brain devices only monitor EEG. However, these bio-signals become much weaker at the BTE location, and their signal quality is more important, being seriously degraded by artifact-related corruptions during daily activities. For this purpose, an offset-compensated auxiliary path (OCAP) and a dual-resolution external positive feedback loop (DR-EPFL) are proposed to boost the input impedance and to improve its AC characteristics further. For small-featured device sizes, the number of electrodes is reduced by utilizing a proposed GSR-embedded ECG readout structure where electrodes are shared and monitored together. For system-level feasibility, a direct-conversion PPG readout with a proposed parasitic capacitance compensation, a transcutaneous vagus-nerve stimulator $(\text{tVNS})$ with an electrode-monitored adaptive charge pump, and a high-resolution bio-impedance channel are integrated together. A BTE-based mental healthcare patch-type device prototype is also manufactured and its multimodal functionality is experimentally verified.
更多
查看译文
关键词
275-fold input impedance,adaptive charge pump,adaptive multimodal compensation capabilities,artifact-related corruptions,behind-the-ear device,behind-the-ear patch-type mental healthcare integrated interface,BTE location,BTE-based measurement,BTE-based mental healthcare patch-type device prototype,continuous mental healthcare platforms,conventional brain activity monitoring devices,conventional brain devices,daily activities,daily-life monitoring applications,direct-conversion PPG readout,dual-resolution external positive feedback loop,electrode-related artifacts,galvanic skin response,GSR-embedded ECG readout structure,head bands,high-resolution bio-impedance channel,motion artifacts,multimodal bio-signals,multimodal functionality,parasitic capacitance compensation,photoplethysmogram,scalp caps,signal quality,small-featured device,wearing discomfort
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要