Spatial Coherence Approaches to Distinguish Suspicious Mass Contents in Fundamental and Harmonic Breast Ultrasound Images

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL(2024)

引用 0|浏览1
暂无评分
摘要
When compared to fundamental B-mode imaging, coherence-based beamforming, and harmonic imaging are independently known to reduce acoustic clutter, distinguish solid from fluid content in indeterminate breast masses, and thereby reduce unnecessary biopsies during a breast cancer diagnosis. However, a systematic investigation of independent and combined coherence beamforming and harmonic imaging approaches is necessary for the clinical deployment of the most optimal approach. Therefore, we compare the performance of fundamental and harmonic images created with short-lag spatial coherence (SLSC), M-weighted SLSC (M-SLSC), SLSC combined with robust principal component analysis with no M-weighting (r-SLSC), and r-SLSC with M-weighting (R-SLSC), relative to traditional fundamental and harmonic B-mode images, when distinguishing solid from fluid breast masses. Raw channel data acquired from 40 total breast masses (28 solid, 7 fluid, 5 mixed) were beamformed and analyzed. The contrast of fluid masses was better with fundamental rather than harmonic coherence imaging, due to the lower spatial coherence within the fluid masses in the fundamental coherence images. Relative to SLSC imaging, M-SLSC, r-SLSC, and R-SLSC imaging provided similar contrast across multiple masses (with the exception of clinically challenging complicated cysts) and minimized the range of generalized contrast-to-noise ratios (gCNRs) of fluid masses, yet required additional computational resources. Among the eight coherence imaging modes compared, fundamental SLSC imaging best identified fluid versus solid breast mass contents, outperforming fundamental and harmonic B-mode imaging. With fundamental SLSC images, the specificity and sensitivity to identify fluid masses using the reader-independent metrics of contrast difference, mean lag one coherence (LOC), and gCNR were 0.86 and 1, 1 and 0.89, and 1 and 1, respectively. Results demonstrate that fundamental SLSC imaging and gCNR (or LOC if no coherence image or background region of interest is introduced) have the greatest potential to impact clinical decisions and improve the diagnostic certainty of breast mass contents. These observations are additionally anticipated to extend to masses in other organs.
更多
查看译文
关键词
Breast imaging,coherence-based beamforming,harmonic imaging,ultrasound
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要