Assessment on compatibility and safety of labels for pharmaceutical packaging.

Chunwang Fu, Fan Jiang, Kun Gao, Xiaobai Xue,Shuo Lei, Chunting Liu, Huan Yu, Hui Wang, Xiaoqian Dong,Jian Jiao, Guojie Liu, Qiang Yang

Journal of pharmaceutical and biomedical analysis(2023)

引用 0|浏览0
暂无评分
摘要
Although the secondary packing materials do not directly contact the finished drug products, compound migration may still happen between them. To ensure drug quality and safety, extractables and leachables of the packing materials should be analyzed. In this study, 2,6-di-tert-butyl-4-methylphenol (BHT) was first found in the labels for pharmaceutical packaging. For the identification of the compound, a strategy combining high performance liquid chromatography (HPLC), ultra-performance liquid chromatography-quadrupole time-of-flight mass (UPLC-Q-TOF-MS) and nuclear magnetic resonance (NMR) spectroscopy was utilized. Afterwards, a effective and sensitive HPLC method for quantification of BHT was developed and validated. Finally, a toxicological risk assessment of BHT was performed to ensure the safety of drugs.
更多
查看译文
关键词
BHT Pharmaceutical packing labels,UPLC-Q-TOF-MS,NMR HPLC