Enhanced monitoring of healthcare shower water in augmented and non-augmented care wards showing persistence of Pseudomonas aeruginosa despite remediation work.

Journal of medical microbiology(2023)

引用 0|浏览9
暂无评分
摘要
in healthcare shower waters presents a high risk of infection to immune-suppressed patients; identifying the colonization-status of water outlets is essential in preventing acquisition. Testing frequencies may be insufficient to capture presence/absence of contamination in healthcare waters between sampling and remediation activities. Standardization of outlets may facilitate the management and control of . This study aims to monitor shower waters and drains for in augmented and non-augmented healthcare settings every 2 weeks for a period of 7 months during remedial actions. All shower facilities were standardized to include antimicrobial silver-impregnated showerhead/hose units, hose-length fixed to 0.8 m and replaced every 3 months. Standard hospital manual decontamination/disinfection occurred daily. Thermostatic-mixer-valves (TMVs) were replaced and disinfected if standard remediation unsuccessful. Of 560 shower and drain samples collected over 14 time-points covering 7 months, colonized 40 %(4/10; non-augmented) and 80 %(8/10; augmented-care) showers in the first week. For each week elapsed, new outlets became contaminated with by 18-19 % (<0.001) in shower waters (OR=1.19; CI=1.09-1.31) and drains (OR=1.18; CI=1.09-1.30). occurrence in shower water was associated with subsequent colonization of the corresponding drain and vice versa (chi-square; <0.001) with simultaneous contamination present in 31 %(87/280) of areas. TMV replacement was ineffective in eradicating colonisation in ~83 % of a subset (6/20; three per ward) of contaminated showers. We demonstrate the difficulties in eradicating from hospital plumbing, particularly when contamination is no longer sporadic. Non-augmented care settings are reservoirs of and should not be overlooked in outbreak investigations. Antimicrobial-impregnated materials may be ineffective once colonization with is established beyond the hose and head. Reducing hose-length insufficient to prevent cross-contamination from shower drains. colonization can be transient in both drain and shower hose/head. Frequent microbiological monitoring suggests testing frequencies following HTM04-01 guidelines are insufficient to capture the colonization-status of healthcare waters between samples. Disinfection/decontamination is recommended to minimize bioburden and the effect of remediation should be verified with microbiological monitoring. Where standard remediation did not remove contamination, intensive monitoring supported justifying replacement of showers and contiguous plumbing.
更多
查看译文
关键词
healthcare shower water,pseudomonas aeruginosa,non-augmented
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要