Comparative Study on Fault-Tolerant Triple Three-Phase PM Machine Drive With Five Modular Windings

IEEE Transactions on Industrial Electronics(2023)

引用 1|浏览9
暂无评分
摘要
In this article, five different triple three-phase windings are presented for fault-tolerant permanent magnet (PM) machine drive to achieve advanced turn short circuit fault (TSCF) current reduction effect. First, the five different winding configurations are briefly introduced and the reasons for the TSCF reduction effect are explained. Then, the healthy performance and fault-tolerant capabilities of several fault modes are investigated by detailed finite element prediction and test verification. They exhibit almost the same healthy performance. It is demonstrated that the zero sequence (ZS) flux linkages in Y-connected winding are the fundamental factor of the huge TSCF current since the Y winding does not contain ZS current path. Thus, the Y -Δ winding exhibits the best TSCF current suppression capability which creates the ZS current path to nullify the ZS flux linkages, and the delta winding ranks as the second which contains a larger ZS circuit. The investigation provides effective approaches and solutions to obtain enhanced fault-tolerant capability on the worst TSCF for safety-critical applications.
更多
查看译文
关键词
Fault current,fault-tolerant,machine winding,permanent magnet (PM) machine drive,turn fault,zero sequence (ZS)