Impact of Increasing Stent Length on Long-Term Clinical Outcomes Undergoing Intracoronary Imaging-Guided Percutaneous Coronary Intervention With New-Generation Drug-Eluting Stents

Yuta Kurosawa,Takeshi Shimizu,Yuya Sakuma, Himika Ohara, Yuki Muto,Yu Sato, Takatoyo Kiko,Akihiko Sato,Tomofumi Misaka,Akiomi Yoshihisa,Kazuhiko Nakazato, Takafumi Ishida,Yasuchika Takeishi

CIRCULATION(2022)

引用 0|浏览6
暂无评分
摘要
Background: While longer stent length of first-generation drug-eluting stents (DES) has been associated with stent-related adverse events, the association between stent length of new-generation DES and clinical outcomes remains controversial. Methods and Results: Consecutive 1403 patients including 2277 lesions who underwent intracoronary imaging-guided percutaneous coronary intervention with 2nd- and 3rd-generation DES were enrolled. Patients were divided into two groups according to total stent length (TSL), and followed up for major adverse cardiovascular events (MACE), defined as a composite of cardiac death, non-fatal myocardial infarction and target lesion revascularization (TLR) for patients. Lesions were divided into two groups according to TSL as well, and followed up for TLR and stent thrombosis. In the per patient analysis, long TSL group (TSL ≥ 32 mm, n = 703) had higher prevalence of diabetes (54.5% vs. 45.2%, P < 0.001), anemia (48.4% vs. 43.0%, P = 0.042), peripheral artery disease (<% vs. 10.6%, P = 0.003), multi-vessel disease (64.7% vs. 36.2%, P < 0.001) and chronic total occlusion (9.5% vs 3.4%, P 0.001) than short TSL group (TSL < 32 mm, n = 691). In the follow up period (mean of 1528 days), MACE and TLR were significantly higher in long TSL group than in short TSL group (P = 0.009 and P = 0.037, respectively). In the multivariate analysis after adjusting for confounding factors, the long TSL was an independent predictor of MACE and TLR (hazard ratio [HR] 1.59, P = 0.002 and HR 1.74, P = 0.047). In the per lesion analysis, Kaplan-Meier curve revealed that TLR was significantly higher in long TSL group (TSL ≥ 26 mm, n = 1160) than short TSL group (TSL < 26mm, n = 1117) (P = 0.017), while stent thrombosis was comparable between the two groups. In the multivariate analysis, TLR was an independent predictor of TLR (HR 1.62, P = 0.029). Conclusion: Longer stent length of new-generation DES was associated with MACE and TLR, but not with stent thrombosis.
更多
查看译文
关键词
stent length,percutaneous intracoronary intervention,stents,long-term,imaging-guided,new-generation,drug-eluting
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要