A pre-time-zero spatiotemporal microscopy technique for the ultrasensitive determination of the thermal diffusivity of thin films

arxiv(2022)

引用 4|浏览16
暂无评分
摘要
Diffusion is one of the most ubiquitous transport phenomena in nature. Experimentally, it can be tracked by following point spreading in space and time. Here, we introduce a spatiotemporal pump-probe microscopy technique that exploits the residual spatial temperature profile obtained through the transient reflectivity when probe pulses arrive before pump pulses. This corresponds to an effective pump-probe time delay of 13 ns, determined by the repetition rate of our laser system (76 MHz). This pre-time-zero technique enables probing the diffusion of long-lived excitations created by previous pump pulses with nanometer accuracy, and is particularly powerful for following in-plane heat diffusion in thin films. In contrast to existing techniques for quantifying thermal transport it does not require any material input parameters or strong heating. We demonstrate the direct determination of the thermal diffusivities of the layered materials MoSe$_2$ (0.18 cm$^2$/s), WSe$_2$ (0.20 cm$^2$/s), MoS$_2$ (0.35 cm$^2$/s), and WS$_2$ (0.59 cm$^2$/s). This technique paves the way for observing novel nanoscale thermal transport phenomena and tracking diffusion of a broad range of species.
更多
查看译文
关键词
thermal diffusivity,spatiotemporal microscopy technique,thin films,ultrasensitive determination,pre-time-zero