Single Line/Phase Open Fault-Tolerant Decoupling Control of a Five-Phase Permanent Magnet Synchronous Motor under Different Stator Connections

ENERGIES(2022)

引用 2|浏览2
暂无评分
摘要
Fault-tolerant control (FTC) of a star-connected Five-phase Permanent Magnet Synchronous Motor (5 phi-PMSM) under open-circuit faults has been extensively studied, among which the decoupled control is attractive and finds a broad application in many fields. Pentacle- and pentagon-connected (generally known as "Penta-connected") 5 phi-PMSMs are popular due to their low voltage and high-power density, and especially, the demanded DC voltage level for the pentacle-connection mode accounting for merely 1/1.9021 of the star-connection mode, which is very appealing today. On the other hand, as one of the recent advances, the fault-tolerant decoupling control for penta-connections is still yet to be reviewed, and so this study investigates this issue and attempts to find the similarities and dissimilarities between star- and penta-connections under either single-line or single-phase open faults. Torque behavior analysis under, respectively, the fault-tolerant MPPT and i(d) = 0 is conducted to confirm the validity of the presented FTC, and it is expected to provide a reference for selecting a 5 phi-PMSM for practical use.
更多
查看译文
关键词
field-oriented control, five-phase permanent magnet synchronous motor, fault-tolerant control, open-circuited fault, pentagon and pentacle connections