Real‐time tissue perfusion assessment using fluorescence imaging topography scanning system: A preclinical investigation

Lasers in Surgery and Medicine(2022)

引用 0|浏览4
暂无评分
摘要
Background and Objectives: We previously developed a real-time fluorescence imaging topography scanning (RFITS) system for intraoperative multimodal imaging, image-guided surgery, and dynamic surgical navigation. The RFITS can capture intraoperative fluorescence, color reflectance, and surface topography concurrently and offers accurate registration of multimodal images. The RFITS prototype is a promising system for multimodal image guidance and intuitive 3D visualization. In the current study, we investigated the capability of the RFITS system in intraoperative fluorescence vascular angiography for real-time assessment of tissue perfusion. Study Design/Materials and Methods: We conducted ex vivo imaging of fluorescence perfusion in a soft casting life-sized human brain phantom. Indocyanine green (ICG) solutions diluted in dimethyl sulfoxide (DMSO) and human serum were injected into the brain phantom through the vessel simulating tube (2 +/- 0.2 mm inner diameter) by an adjustable flow peristaltic pump. To demonstrate the translational potential of the system, an ICG/DMSO solution was perfused into blood vessels of freshly harvested porcine ears (n = 9, inner diameter from 0.56 to 1.27 mm). We subsequently performed in vivo imaging of fluorescence-perfused vascular structures in rodent models (n = 10). 5 mg/ml ICG solutions prepared in sterile water were injected via the lateral tail vein. All targets were imaged by the RFITS prototype at a working distance of 350-400 mm. Results: 3D visualization of 10 mu g/ml ICG-labeled continuous moving serum in the brain phantom was obtained at an average signal-to-background ratio (SBR) of 1.74 +/- 0.03. The system was able to detect intravenously diffused fluorescence in porcine tissues with an average SBR of 2.23 +/- 0.22. The RFITS prototype provided real-time monitoring of tissue perfusion in rats after intravenous (IV) administration of ICG. The maximum fluorescence intensity (average SBR = 1.94 +/- 0.16, p < 0.001) was observed at T-peak of similar to 30 seconds after the ICG signal was first detected (average SBR = 1.19 +/- 0.13, p < 0.01). Conclusions: We have conducted preclinical studies to demonstrate the feasibility of applying the RFITS system in real-time fluorescence angiography and tissue perfusion assessment. Our system provides fluorescence/color composite images for intuitive visualization of tissue perfusion with 3D perception. The findings pave the way for future clinical translation.
更多
查看译文
关键词
fluorescence angiography, multimodal imaging, tissue perfusion, topography imaging
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要