Performance enhancement of a split air conditioner using porous material inside the evaporator pipes

HEAT TRANSFER(2022)

引用 3|浏览4
暂无评分
摘要
In this experimental study, a porous material is used inside the pipes of the evaporator as the main heat exchanging device in the air conditioning cycle. The used porous material consists of stainless steel balls of different diameters. As a case study, refrigerant R454B, which is a drop-in replacement to refrigerant R410A, is used as a working fluid in the air conditioner thermodynamic cycle. Four different porosities were used during the experimental tests; 100% (empty tube), 46%, 40%, and 33%. This study investigated the influence of variation of porosity as well as outside air temperature and refrigerant evaporation temperature on the cycle coefficient of performance, evaporation capacity, pressure drop, and power consumption during the compression process. Measured evaporation temperatures and indoor temperatures during tests were in the range of 1.5-12 degrees C and 18-25 degrees C, respectively. The use of porous material in the evaporation heat exchanger resulted in a considerable increase in the cycle evaporation capacity and coefficient of performance. Varying porosity from 100% to 33% resulted in an average percent increase of cycle evaporation capacity and coefficient of performance by 48.8% and 84.3%, respectively. Also, decreasing porosity from 100% to 33% resulted in an average percent increase in power consumption during the compression process by about 27%. An average percent increase of power consumption of compressor by about 25.9% is also reported, when evaporation temperature increased from 1.5 degrees C to 12 degrees C. Increasing outside air temperature from 27.1 degrees C to 39.5 degrees C resulted in decreasing evaporation capacity and coefficient of performance by 35.2% and 34.5%, respectively, and in increasing compressor power consumption by about 14.3%. A considerable pressure drop was recorded during the evaporation process when using porous material. The volumetric evaporation capacity, as well as compressor discharge temperature, are increased by increasing evaporating temperature and by decreasing evaporator porosity. The increase in air ambient temperature resulted in a considerable increase in refrigerant mass flow rate.
更多
查看译文
关键词
coefficient of performance, evaporation capacity, performance enhancement, porous evaporator, pressure drop, R454B, split air conditioner
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要