Study of Energy Efficiency Benchmarking Parameter based on Real Traffic and Energy Data of a high-speed Traction Lift in Hong Kong

Melvyn Long Ho Ng,Albert So

Transportation Systems in Buildings(2020)

引用 0|浏览0
暂无评分
摘要
A holistic normalization method (So et al 2005, Lam et al 2006) was developed, which can simultaneously assess both drive efficiency and traffic control performance on a real-time basis of a lift system, termed measured in the unit, J/kg/m. Since 2012, it has been adopted by the HKSAR Government as an emerging good engineering practice in the Technical Guidelines of the Building Energy Code . A study of the parameter based on pure simulations using artificial traffic patterns and simple energy patterns was conducted (So et al 2018), recommending that a value of 40 J/kg/m could indicate an efficient system. In this article, the study is conducted again based on real passenger demand and real energy profiles on a bank of seven lifts serving a super-high-rise luxurious office building in Hong Kong, with a conclusion that the previous recommendation is still valid, supported by real data. The study includes variation by simulation in traffic control algorithms and the number of lifts of the bank to study the undersizing effect with the same passenger demands throughout a typical weekday, from morning to evening.
更多
查看译文
关键词
energy efficiency benchmarking parameter,energy efficiency,energy data,high-speed
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要