Effect of Transcutaneous Magnetic Stimulation in Patients With Ventricular Tachycardia Storm A Randomized Clinical Trial

JAMA CARDIOLOGY(2022)

引用 7|浏览13
暂无评分
摘要
IMPORTANCE Autonomic neuromodulation provides therapeutic benefit in ventricular tachycardia (VT) storm. Transcutaneous magnetic stimulation (TcMS) can noninvasively and nondestructively modulate a patient's nervous system activity and may reduce VT burden in patients with VT storm. OBJECTIVE To evaluate the safety and efficacy of TcMS of the left stellate ganglion for patients with VT storm. DESIGN, SETTING, AND PARTICIPANTS This double-blind, sham-controlled randomized clinical trial took place at a single tertiary referral center between August 2019 and July 2021. The study included 26 adult patients with 3 or more episodes of VT in 24 hours. INTERVENTIONS Patients were randomly assigned to receive a single session of either TcMS that targeted the left stellate ganglion (n = 14) or sham stimulation (n = 12). MAIN OUTCOMES AND MEASURES The primary outcomewas freedom from VT in the 24-hour period following randomization. Key secondary outcomes included safety of TcMS on cardiac implantable electronic devices, as well as burden of VT in the 72-hour period following randomization. RESULTS Among 26 patients (mean [SD] age, 64 [13] years; 20 [ 77%] male), a mean (SD) of 12.7 (10.3) episodes of VT occurred within the 24 hours preceding randomization. Patients had recurrent VT despite taking a mean (SD) of 2.0 (0.6) antiarrhythmic drugs (AADs), and 11 patients (42%) required mechanical hemodynamic support at the time of randomization. In the 24-hour period after randomization, VT recurred in 4 of 14 patients (29% [SD 47%]) in the TcMS group vs 7 of 12 patients (58%[SD 51%]) in the sham group (P =.20). In the 72-hour period after randomization, patients in the TcMS group had a mean (SD) of 4.5 (7.2) episodes of VT vs 10.7 (13.8) in the sham group (incidence rate ratio, 0.42; P <.001). Patients in the TcMS group were taking fewer AADs 24 hours after randomization compared with baseline (mean [SD], 0.9 [0.8] vs 1.8 [0.4]; P =.001), whereas there was no difference in the number of AADs taken for the sham group (mean [SD], 2.3 [0.8] vs 1.9 [0.5]; P =.20). None of the 7 patients in the TcMS group with a cardiac implantable electronic device had clinically significant effects on device function. CONCLUSIONS AND RELEVANCE In this randomized clinical trial, findings support the potential for TcMS to safely reduce the burden of VT in the setting of VT storm in patients with and without cardiac implantable electronic devices and inform the design of future trials to further investigate this novel treatment approach.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要