Machine learning-based diagnostic evaluation of shear-wave elastography in BI-RADS category 4 breast cancer screening: a multicenter, retrospective study

Yi Tang,Minjie Liang, Li Tao, Minjun Deng,Tianfu Li

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY(2022)

引用 6|浏览5
暂无评分
摘要
Background: Ultrasound is commonly used in breast cancer screening but lacks quantification ability and diagnostic power due to its low specificity, which can lead to overdiagnosis and unnecessary biopsies. This study evaluated the diagnostic efficacy and clinical utility of adding shear-wave elastography (SWE) to the screening of the Breast Imaging Reporting and Data System (BI-RADS) category 4 breast cancer. Methods: A machine learning-based diagnostic model was constructed using data retrospectively collected from 3 independent cohorts with features selected using lasso regression and support vector machine-recursive feature elimination algorithms. Propensity score matching (PSM) was used to preclude confounding baseline characteristics between malignant and benign lesions. A decision curve analysis (DCA) was used to evaluate the clinical benefit of the diagnostic model in identifying high-risk tumor patients for intervention while simultaneously avoiding overtreatment of low-risk patients with integrative evaluation using a net benefit value and treatment reduction rate. Results: In our training center, a total of 122 patients were enrolled, and 577 breast tumors were collected. The comparison between malignant and benign lesions revealed significant differences in patient age, tumor size, resistance index (RI), and elasticity values. The maximum elasticity value (Emax) was identified as an independent diagnostic feature and was included in the diagnostic model. The combination of Emax with BI-RADS category 4 demonstrated a significantly better diagnostic efficacy than the BI-RADS category alone [BI-RADS+Emax: AUC: 0.908, 95% confidence interval (CI), 0.842-0.974; BI-RADS: AUC =0.862, 95% CI, 0.784-0.94; P=0.024] and significantly increased the clinical benefit for patients and policy makers by effectively reducing overdiagnosis and biopsy rates. In the BI-RADS category 4A subgroup, adding Emax to breast cancer screening benefited patients and showed a greater absolute benefit than did the BI-RADS category alone when used for patients with a higher probability of cancer (>0.403), demonstrating a 50% overtreatment reduction. Conclusions: Adding Emax to BI-RADS category 4 breast cancer screening using SWE significantly reduced overdiagnosis and biopsy rates compared with the BI-RADS category alone, especially for BI-RADS 4A patients.
更多
查看译文
关键词
Ultrasound, shear-wave elastography (SWE), breast cancer, cancer screening, Breast Imaging Reporting and Data System (BI-RADS)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要