Oscar Augusto De Aguiar Francisco,Wiktor Byczynski,Kazu Akiba, Claudia Bertella, Alexander Bitadze, Matthew Brock, Bartosz Bulat, Guillaume Button,Jan Buytaert,Stefano De Capua,Riccardo Callegari, Christine Castellana, Andrea Catinaccio, Catherine Charrier, Collette Charvet,Victor Coco,Paula Collins, Jordan Degrange,Raphael Dumps, Diego Alvarez Feito, Julian Freestone,Mariusz Jedrychowski,Vinicius Franco Lima, Abraham Gallas,Wouter Hulsbergen,Daniel Hynds, Gonzalo Arnau Izquierdo,Pawel Jalocha, Eddy Jan,Malcolm John,Nathan Jurik, Alexander Leflat,Edgar Lemos Cid,Rolf Lindner,Alessandro Mapelli, Jerome Noel,Andrei Nomerotski, Rui de Oliveira, Martijn van Overbeek,Chris Parkes,Paolo Petagna, Alexandre Porret, Denis Renaud, Erno Roeland,Giulia Romagnoli, Eric Rouchouze, Krista de Roo,Freek Sanders,Thomas Schneider,Heinrich Schindler,Burkhard Schmidt, Andreas Schopper,Luke Scantlebury-Smead, Miranda Van Stenis,Peter Svihra,Benoit Teissandier, Jean-Francois Teissier, Xavier Thery,Eric Thomas,Bart Verlaat

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2022)

引用 5|浏览10
暂无评分
摘要
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase CO2 for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures was completed in September 2021. This article describes the R&D path supporting the microchannel production and assembly and the motivation for the design choices, together with the achieved fluidic and thermal performance. The Thermal Figure of Merit of the microchannel coolers is measured on the final modules to be between 1.5 and 3.5 K cm2 W−1, depending on glue thickness. The microchannel coolers constitute 18% of the total radiation length of the VELO and less than 2% of the material seen before the second measured point on the tracks. Microchannel cooling is well suited to the VELO implementation due to the uniform mass distribution, close thermal expansion match with the module components and resistance to radiation.
更多
查看译文
关键词
Microchannel cooling,Bi-phase CO2,Silicon wafer bonding,Thermal figure of merit,VELO upgrade
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要