Development of a miniaturized robotic guidance device for stereotactic neurosurgery

JOURNAL OF NEUROSURGERY(2022)

引用 3|浏览5
暂无评分
摘要
OBJECTIVE Consistently high accuracy and a straightforward use of stereotactic guidance systems are crucial for pre-cise stereotactic targeting and a short procedural duration. Although robotic guidance systems are widely used, currently available systems do not fully meet the requirements for a stereotactic guidance system that combines the advantages of frameless surgery and robotic technology. The authors developed and optimized a small-scale yet highly accurate guid-ance system that can be seamlessly integrated into an existing operating room (OR) setup due to its design. The aim of this clinical study is to outline the development of this miniature robotic guidance system and present the authors' clinical experience. METHODS After extensive preclinical testing of the robotic stereotactic guidance system, adaptations were implement-ed for robot fixation, software usability, navigation integration, and end-effector application. Development of the robotic system was then advanced in a clinical series of 150 patients between 2013 and 2019, including 111 needle biopsies, 13 catheter placements, and 26 stereoelectroencephalography (SEEG) electrode placements. During the clinical trial, con-stant modifications were implemented to meet the setup requirements, technical specifications, and workflow for each indication. For each application, specific setup, workflow, and median procedural accuracy were evaluated. RESULTS Application of the miniature robotic system was feasible in 149 of 150 cases. The setup in each procedure was successfully implemented without adding significant OR time. The workflow was seamlessly integrated into the preexisting procedure. In the course of the study, procedural accuracy was improved. For the biopsy procedure, the real target error (RTE) was reduced from a mean of 1.8 +/- 1.03 mm to 1.6 +/- 0.82 mm at entry (p = 0.05), and from 1.7 +/- 1.12 mm to 1.6 +/- 0.72 mm at target (p = 0.04). For the SEEG procedures, the RTE was reduced from a mean of 1.43 +/- 0.78 mm in the first half of the procedures to 1.12 +/- 0.52 mm (p = 0.002) at entry in the second half, and from 1.82 +/- 1.13 mm to 1.57 +/- 0.98 mm (p = 0.069) at target, respectively. No healing complications or infections were observed in any case. CONCLUSIONS The miniature robotic guidance device was able to prove its versatility and seamless integration into preexisting workflow by successful application in 149 stereotactic procedures. According to these data, the robot could significantly improve accuracy without adding time expenditure. https://thejns.org/doi/abs/10.3171/2021.9.JNS21794
更多
查看译文
关键词
robotic device, stereotactic neurosurgery, miniature, accuracy, surgical technique
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要