Free-Breathing R-2* Mapping Of Hepatic Iron Overload In Children Using 3d Multi-Echo Ute Cones Mri

MAGNETIC RESONANCE IN MEDICINE(2021)

引用 7|浏览45
暂无评分
摘要
Purpose: To enable motion-robust, ungated, free-breathing R-2* mapping of hepatic iron overload in children with 3D multi-echo UTE cones MRI.Methods: A golden-ratio re-ordered 3D multi-echo UTE cones acquisition was developed with chemical-shift encoding (CSE). Multi-echo complex-valued source images were reconstructed via gridding and coil combination, followed by confounder-corrected R-2* (=1/T-2*) mapping. A phantom containing 15 different concentrations of gadolinium solution (0-300 mM) was imaged at 3T. 31) multi-echo UTE cones with an initial TE of 0.036 ms and Cartesian CSE-MRI (IDEAL-IQ) sequences were performed. With institutional review board approval, 85 subjects (81 pediatric patients with iron overload + 4 healthy volunteers) were imaged at 3T using 3D multi-echo UTE cones with free breathing (FB cones), IDEAL-IQ with breath holding (BH Cartesian), and free breathing (FB Cartesian). Overall image quality of R-2* maps was scored by 2 blinded experts and compared by a Wilcoxon rank-sum test. For each pediatric subject, the paired R-2* maps were assessed to determine if a corresponding artifact-free 15 mm region-of-interest (ROI) could be identified at a mid-liver level on both images. Agreement between resulting R-2* quantification from FB cones and BH/FB Cartesian was assessed with Bland-Altman and linear correlation analyses.Results: ROI-based regression analysis showed a linear relationship between gadolinium concentration and R-2* in IDEAL-IQ (y = 8.83x - 52.10, R-2 = 0.995) as well as in cones (y = 9.19x - 64.16, R-2 = 0.992). ROI-based Bland-Altman analysis showed that the mean difference (MD) was 0.15% and the SD was 5.78%. However, IDEAL-IQ R-2* measurements beyond 200 mM substantially deviated from a linear relationship for IDEAL-IQ (y = 5.85x + 127.61, R-2 = 0.827), as opposed to cones (y = 10.87x - 166.96, R-2 = 0.984). In vivo, FB cones R-2* had similar image quality with BH and FB Cartesian in 15 and 42 cases, respectively. FB cones R-2* had better image quality scores than BH and FB Cartesian in 3 and 21 cases, respectively, where BH/FB Cartesian exhibited severe ghosting artifacts. ROI-based Bland-Altman analyses were 2.239; (MD) and 6.59% (SD) between FB cones and BH Cartesian and were 0.21% (MD) and 7.02% (SD) between FB cones and FB Cartesian, suggesting a good agreement between FB cones and BH (FB) Cartesian R-2*. Strong linear relationships were observed between BH Cartesian and FB cones (y = 1.00x + 1.07, R-2 = 0.996) and FB Cartesian and FB cones (y = 0.98x + 1.68, R-2 = 0.999).Conclusion: Golden-ratio re-ordered 3D multi-echo UTE Cones MRI enabled motion-robust, ungated, and free-breathing R-2* mapping of hepatic iron overload, with comparable R-2* measurements and image quality to BH Cartesian, and better image quality than FB Cartesian.
更多
查看译文
关键词
3D multi-echo UTE cones k-space sampling trajectory, chemical-shift-encoded MRI, confounder-corrected R-2*, free-breathing liver R-2* mapping, hepatic iron overload
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要