Comparing Accuracy of Thermoplastic Mask versus Commercial Bra for the Immobilization of Pendulous Breast During Radiation Therapy Treatment: A Retrospective Cohort Study

Zaheeda Mulla,Omar Iskanderani,Amina Weber, Abdullah AlMohammed, Mohammed Sheikh Al-Amoodi,Shamel Soaida

Advances in Radiation Oncology(2021)

引用 1|浏览2
暂无评分
摘要
Purpose: This study aimed to compare thermoplastic mask with bra in terms of setup reproducibility and immobilization of pendulous breasts during radiation therapy (RT).Methods and materials: Forty-two female patients with breast cancer treated with either intensity modulated RT or 3-dimensional conformal RT were retrospectively reviewed. Of these, 21 benefited from thermoplastic mask immobilization and 21 used a bra. Setup accuracy was evaluated using consecutive cone beam computed tomography/electronic portal imaging device sessions over the first 3 days before treatment (systematic setting), followed by weekly cone beam computed tomography/electronic portal imaging device (random settings), and compared with the reference image to calculate the corresponding translational shift (setup error) in the 3 planes. Average absolute shift values in both systematic and random settings were compared between the 2 groups. Accuracy was analyzed by comparing the percentage of pooled settings within +/- 0.05 and +/- 0.1 cm of the reference image.Results: Compared with a bra, use of the mask was associated with a smaller longitudinal shift in systematic settings (difference in mean: 0.27 cm; P = .027; Mann-Whitney U test) and a lesser lateral shift in random setting (difference in mean: 0.19 cm; P = .005; Mann-Whitney U test). In the pooled systematic settings, the mask performed relatively better than the bra in the lateral and longitudinal planes, with no statistical significance. In pooled random settings, mask showed greater accuracy than bra in the lateral plane with 86.0% versus 58.9% accuracy at +/- 0.5 cm (P < .001) and 48.8% versus 21.7% accuracy at +/- 0.1 cm (P < .001), respectively. There was no significant difference in the incidence of radiodermatitis between the 2 groups. However, a hypofractionation regimen was associated with a lower incidence of radiodermatitis, and the severity of skin reactions was positively correlated with treatment dose (unstandardized regression coefficient: B = .001; correlation coefficient: r = .571; P < .001).Conclusions: Masks provide superior reproducibility compared with commercially available bras. (C) 2020 The Author(s). Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要