摘要
An important consideration when designing a magnetostatic cavity for various applications is to maximize the ratio of the volume of field homogeneity to the overall size of the cavity. We report a design of a magnetically shielded solenoid that significantly improves the transverse field gradient averaged over a volume of 1000 cm(3) by placing compensation coils around the holes in the mu-metal end caps rather than the conventional design in which the compensation coils are placed on the main solenoid. Our application is polarized He-3-based neutron spin filters, and our goal was to minimize the volume-averaged transverse field gradient, thereby the gradient induced relaxation time, over a He-3 cell. For solenoids with end cap holes of different sizes, additional improvements in the field gradient were accomplished by introducing non-identical compensation coils centered around the non-identical holes in the end caps. The improved designs have yielded an overall factor of 7 decrease in the gradient in the solenoid, hence a factor of 50 increase in the gradient induced relaxation time of the He-3 polarization. The results from both simulation and experiments for the development of several such solenoids are presented. Whereas our focus is on the development of magnetically shielded solenoids for He-3 neutron spin filters, the approach can be applied for other applications demanding a high level of field homogeneity over a large volume.