Feasibility Study On The Use Of Cmos Sensors As Detectors In Radioguided Surgery With Beta(-)- Emitters

APPLIED RADIATION AND ISOTOPES(2020)

引用 4|浏览40
暂无评分
摘要
Radioguided surgery (RGS) is a medical practice which thanks to a radiopharmaceutical tracer and a probe allows the surgeon to identify tumor residuals up to a millimetric resolution in real-time. The employment of beta(-) emitters, instead of gamma or beta(+), reduces background from healthy tissues, administered activity to the patient, and medical exposure. In a previous work the possibility of using a CMOS Imager (Aptina MT9V011), initially designed for visible light imaging, to detect beta(-) from Y-90 or Sr-90 sources has been established. Because of its possible application as counting probe in RGS, the performances of MT9V011 in clinical-like conditions were studied.(1)Through horizontal scans on a collimated( 90)Sr source of different sizes (1, 3, 5, 7 mm), we have determined relationships between scan fit parameters and the source dimension, namely A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter, are determined. Horizontal scan measurements on a source, interposing collimators of different size, aim to determine relationships or correlations between scan fit parameters and source dimension. A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter are determined.In order to get closer to clinical conditions, agar-agar phantoms containing Y-90 with different dimensions and activities were prepared. A Y-90 phantom is characterized by a central spot and a ring all around, for simulating both signal (tumor) and background (surrounding healthy tissue). The relationship found between scan maximum and Sr-90 source diameter is then exploited to extract the concentration ratio between spot and external ring of the Y-90 phantom. This observable, defined as the ratio between the tumor and the nearby healthy tissues uptake simulates the Tumor-to-Non-tumor Ratio (TNR). With the aim of evaluating the sensor's ability to discriminate signal from background relying on the significance parameter, a further Y-90 phantom, featuring a well-known and clinical-like activity will mimic the signal only condition. This result is used to extrapolate to different source sizes, after having estimated the background for various TNR. The obtained significance values suggest that the MT9V011 sensor is capable of distinguishing a signal from an estimated background, depending on the interplay among TNR, acquisition time and tumor diameter.
更多
查看译文
关键词
CMOS sensors, Radioguided surgery, beta(-) radiation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要