High-rate measurements of the novel BAND-GEM technology for thermal neutron detection at spallation sources

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2020)

引用 3|浏览93
暂无评分
摘要
Thermal neutron detection technologies alternative to 3He, featuring a rate capability matching the high flux expected at the European Spallation Source (ESS), are one of the main present challenges of neutron science. A new thermal neutron detection technology was recently developed named the BAND-GEM, a Gas Electron Multiplier (GEM)-based detector provided with a borated 3D converter to reach high efficiency. In this paper the results of a count rate test performed on the BAND-GEM at the ORPHEE reactor are presented. The results show that the detector can easily reach a neutron count rate of 2 MHz/cm2 while maintaining a good linearity and it is able to reach 8 MHz/cm2 with a measurable loss of linearity η and with no sign of instability.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper