Stabilization and transdermal delivery of an investigational peptide using MicroCor® solid-state dissolving microstructure arrays.

Journal of Pharmaceutical Sciences(2020)

引用 4|浏览9
暂无评分
摘要
The formulation of biotherapeutics presents unique challenges especially with regard to physical and chemical stability and often requires refrigerated storage conditions of final drug products. Peptide A is an example of a developmental compound which showed significant stability challenges when prepared as a liquid formulation for a subcutaneous injection. The aim of the present study was to evaluate whether Peptide A can be successfully formulated in MicroCor® microstructure arrays (MSAs) as an alternative delivery option. MSAs contain a high density of dissolving microstructures allowing for transdermal delivery. In the present work, a 5600-needle MSA (~200 μm long microstructures, 2 cm2 array) was prepared with a therapeutically-relevant dose of Peptide A. The array was shown to be stable under room-temperature storage conditions for 3 months. On in vivo application to Yucatan minipigs, Peptide-A-loaded MSAs demonstrated only mild and transient skin irritation and a very high efficiency of peptide transfer from dissolving microstructures into the skin resulting in absolute bioavailability of 74%. This transdermal bioavailability was very similar to the 73% bioavailability obtained from a subcutaneous injection. This technical feasibility study demonstrated that MicroCor® technology represents a viable option for delivery of Peptide A with significant improvements in peptide stability.