Experimental Investigation On The Performance And Durability Of Hydrogen Aemfc With Electrochemical Impedance Spectroscopy

INTERNATIONAL JOURNAL OF ENERGY RESEARCH(2019)

引用 16|浏览3
暂无评分
摘要
In situ experimental tests and scanning electron microscope (SEM) observations are done to explore the impact of geometry structure and operating conditions on the performance and durability of alkaline electrolyte membrane fuel cell (AEMFC) accompanied by electrochemical diagnosis. The results show that low anode and cathode polarization resistances can be achieved by selecting a proper ionomer mass fraction (IMF) of the catalyst layer (CL). Increasing the IMF can improve the tolerance to inlet gas humidity. The presence of the anode microporous layer (MPL) greatly improves the cell performance, but cathode MPL plays a reverse effect. After the durability test, the homogeneity of CL is seriously deformed, leading to a great increment of anode and cathode polarization resistances, verified by the electrochemical impedance spectroscopy (EIS) and SEM results. An enhancement of fuel cell durability is achieved by adding nanoscale polytetrafluoroethylene (PTFE) into CL. This work can provide some guidance for the structural and operating parameter optimization of the AEMFC researches in the future.
更多
查看译文
关键词
alkaline fuel cell, electrochemical analysis, ionomer mass fraction, microporous layer, scanning electron microscope