Low molecular weight PEG-PLGA polymers provide a superior matrix for conjugated polymer nanoparticles in terms of physicochemical properties, biocompatibility and optical/photoacoustic performance.

JOURNAL OF MATERIALS CHEMISTRY B(2019)

引用 31|浏览8
暂无评分
摘要
The near-infrared absorbing conjugated polymer poly[2,6-(4,4-bis-(2-ethylhexyl)-4H-cyclopenta[2,1-b;3,4-b ']-dithiophene)-alt-4,7-(2,1,3-benzothiadiazole)] (PCPDTBT) has been investigated as a contrast agent for optical and photoacoustic imaging. Lipophilic pi-conjugated polymers can be efficiently encapsulated within self-assembling diblock copolymer poly(ethylene glycol) methyl ether-block-poly(lactide-co-glycolide) (PEG-PLGA) nanoparticles, although the effect of variations in PEG and PLGA chain lengths on nanoparticle properties, performance and biocompatibility have not yet been investigated. In this study, PEG-PLGA with different block lengths (PEG(2kDa)-PLGA(4kDa), PEG(2kDa)-PLGA(15kDa) and PEG(5kDa)-PLGA(55kDa)) were used to encapsulate PCPDTBT. Nanoparticle sizes were smallest (<100 nm) when using PEG(2kDa)-PLGA(4kDa), with <5% PCPDTBT content and a reduction in the total solids concentration of the organic phase. All PEG-PLGA nanoparticles were colloidally stable in water and serum-supplemented cell culture medium over 24 h at 37 degrees C, with slight evidence of protein surface adsorption. PEG(2kDa)-PLGA(4kDa) systems showed a threefold lower cytotoxicity (IC50 value) than the other two systems. Haemolytic activity was <2.5% for all systems and no platelet aggregation or inhibition of ADP-induced platelet aggregation was observed. Encapsulation of PCPDTBT within a PEG-PLGA matrix shifted fluorescence emission towards red wavelengths (760 nm in THF vs. 840 nm in nanoparticles) and reduced the quantum yield by 30-70-fold compared to THF. Nonetheless, PCPDTBT:PEG(2kDa)-PLGA(4kDa) systems had a marginally higher quantum yield and signal-to-background ratio in a phantom mouse compared with PEG(2kDa)-PLGA(15kDa) and PEG(5kDa)-PLGA(55kDa) systems. As a photoacoustic imaging probe, PCPDTBT:PEG(2kDa)-PLGA(4kDa) systems also showed a higher photoacoustic amplitude compared to higher molecular weight PEG-PLGA systems. Overall, the low molecular weight PEG(2kDa)-PLGA(4kDa) nanoparticle systems conferred the benefits of smaller sizes, reduced cytotoxicity and enhanced imaging performance compared to higher molecular weight matrix polymers.
更多
查看译文
关键词
polymers nanoparticles,peg–plga polymers,low molecular weight peg–plga
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要