Determination Of K(Qmsr, Q0)(Fmsr, Fref) Factors For Ion Chambers Used In The Calibration Of Leksell Gamma Knife Perfexion Model Using Egsnrc And Penelope Monte Carlo Codes

MEDICAL PHYSICS(2018)

引用 16|浏览6
暂无评分
摘要
PurposeTo calculate the k(Qmsr, Q0)(fmsr, fref) factors for nine common ionization chamber types following the small fields dosimetry formalism for the calibration of the Leksell Gamma Knife((R))(LGK) Perfexion(TM) using Monte Carlo simulation. This study also provides the first independent comparison of EGSnrc and PENELOPE for the calculation of k(Qmsr, Q0)(fmsr, fref) correction factors and proposes a practical method to predict these factors based on chamber type, chamber orientation and phantom electron density.MethodsThe ionization chambers are modeled using the EGSnrc and PENELOPE Monte Carlo codes based on the blueprints provided by the manufacturers. The chambers are placed in a half-sphere water phantom and five spherical phantoms made of liquid water, solid water, ABS, polystyrene, and PMMA, respectively. Dose averaged over the air cavity of the chambers and a small water volume are calculated using EGSnrc and PENELOPE Monte Carlo codes for both conventional and machine specific reference (msr) setups. Using the calculated dose ratio, the k(Qmsr, Q0)(fmsr, fref) factor is determined for all phantom materials and two possible orientations of chamber. The calculated k(Qmsr, Q0)(fmsr, fref) factors are compared to a previous Monte Carlo study. A relationship between the k(Qmsr, Q0)(fmsr, fref) factor and the electron density of the phantom material is derived to predict the k(Qmsr, Q0)(fmsr, fref) factor for any phantom material type. Applying the calculated k(Qmsr, Q0)(fmsr, fref) factors to the measured dose rate of a recent round robin study improves consistency of reference dosimetry of the Leksell Gamma Knife((R))(LGK) Perfexion(TM).ResultsAgreement within uncertainty is observed between k(Qmsr, Q0)(fmsr, fref) values determined in this study and the previous PEGASOS/PENELOPE study in a liquid water phantom. The difference between k(Qmsr, Q0)(fmsr, fref) values in parallel and perpendicular detector orientations is most significant for the PTW 31010 (1.8%) chamber. The percentage root-mean-square (%RMS) deviation between EGSnrc and PENELOPE calculated k(Qmsr, Q0)(fmsr, fref) values for Exradin-A1SL, A14 and A14SL chambers studies in this work was found to be 0.4%. The k(Qmsr, Q0)(fmsr, fref) values increase linearly with electron density of the phantom material for all chamber types mainly due to the linear dependency of photon energy fluence ratios on electron density. The average percentage difference between the calculated and predicted k(Qmsr, Q0)(fmsr, fref) values using two methods is found to be 0.15% and 0.16%. Previously measured dose rates corrected with the k(Qmsr, Q0)(fmsr, fref) values determined in this work leads to absorbed dose values consistent to within 0.8%.ConclusionsThe calculated k(Qmsr, Q0)(fmsr, fref) values in this work will enable users to apply the appropriate correction for their own specific phantom material only knowing the electron density of the phantom material.
更多
查看译文
关键词
Leksell Gamma Knife perfexion, calibration, Monte Carlo, k(Qmsr, Q0)(fmsr, fref)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要