A meta-analysis of transcatheter device closure of perimembranous ventricular septal defect

International Journal of Cardiology(2018)

引用 77|浏览12
暂无评分
摘要
Background While transcatheter device closure of ventricular septal defects (VSDs) is gaining popularity, concerns remain about adverse events; particularly heart block in peri-membranous VSDs (pmVSDs). The aim of this study is to ascertain outcomes of transcatheter device closure of pmVSDs through a meta-analysis of current literature. Methods A PubMed and Scopus search for studies in English on device closure of pmVSDs published till end-February 2017 was performed. Exclusion criteria included case series already included in multi-centre studies, sample size <5, and VSD acquired following myocardial infarction. Pooled estimates of success and complications was obtained using the random effects model. Results A total of 54 publications comprising 6762 patients with pmVSDs were included. The mean age of patients ranged from 1.6 to 37.4years. The pooled estimate of successful device implantation is 97.8% (95% CI: 96.8 to 98.6). The most common complication is residual shunt (15.9%; 95% CI: 10.9 to 21.5). Other complications include arrhythmias (10.3%; 95% CI: 8.3 to 12.4) and valvular defects (4.1%; 95% CI: 2.4 to 6.1). The pooled estimate of complete atrioventricular block (cAVB) is 1.1% (95% CI: 0.5 to 1.9). Conclusion Our meta-analysis suggests that device closure of pmVSDs is a safe and effective procedure. The complication of cAVB is low but significant. The risk is expected to further reduce with newer devices which are less stiff with improved profiles. Further studies validating this will be useful in formulating guidelines for device closure of pmVSDs.
更多
查看译文
关键词
Closure,Peri-membranous,Ventricular septal defect
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要