In this paper, a voltage source type high-frequency inverter operating at ZVS scheme is presented for driving a silent discharge (SD) type ozone generating tube load. An optimum design procedure of the series compensated resonant inductor which is specified for the capacitive load modeling of ozone generating tube is described herein. The effective discrete pulse modulated power regulation characteristics of voltage-fed load resonant inverter operating under PDM (pulse density modulation), PWM and PFM hybrid control strategy are illustrated along with its performances. This hybrid control treated here is more effective in achieving zero voltage switching, which can reduce switching losses and electromagnetic noise
更多
查看译文
关键词
gas-discharge tubes,invertors,ozone,pulse modulation,resonant power convertors,switching circuits,pfm hybrid control,pwm,zvs,capacitive load modeling,discrete pulse modulated inverter,high-frequency soft-switching inverter,optimum design procedure,ozone generating tube,power regulation,pulse density modulation,series compensated resonant inductor,silent discharge ozone generating tube,voltage source type high-frequency inverter,voltage-fed load resonant inverter,high frequency,resonant inverters,inductors,resonance