Collapsed regime operation of capacitive micromachined ultrasonic transducers based on wafer-bonding technique

Ultrasonics, 2003 IEEE Symposium(2003)

引用 16|浏览6
暂无评分
摘要
We report experimental results from collapsed regime operation of the capacitive micromachined ultrasonic transducers (cMUTs) fabricated by a wafer bonding technique. The results show that a cMUT operating in the collapsed regime produces a maximal output pressure higher than a cMUT operating in the precollapse regime at 90% of its collapse voltage, 1.79kPa/V vs. 9.72 kPa/V at 2.3 MHz. in collapsed regime operation the fractional bandwidth (pulse-echo) is increased compared to that obtained in precollapsed regime operation 140% vs 83% with a bias 90% of the collapse voltage. Characterization of 1-D cMUT arrays operating in oil was done by ultrasonic pulse echo and pitch catch measurements.
更多
查看译文
关键词
capacitive sensors,micromachining,semiconductor device testing,ultrasonic transducers,wafer bonding,2.3 mhz,capacitive micromachined ultrasonic transducers,collapse voltage,collapsed regime operation,pitch catch measurements,precollapse regime,ultrasonic pulse echo