Digital correction method for an H-field sensor in power system EMC measurements

Power Delivery, IEEE Transactions(2004)

引用 2|浏览2
暂无评分
摘要
Analysis was conducted on the nature and characteristics of an H-field sensor for power system electromagnetic compatibility (EMC) measurements. Based on the original calibrated response curve of the magnetic-field (H) sensor and steepest descent theory, an analog model has been created to represent the sensor's transfer function. This function was converted into a set of digital algorithms by the bilinear transformation method, thus allowing subsequent signal processing on available software. The digital correction model for the sensor gives an estimated error of within 8% for all the relevant frequency components. The results present some general analysis methods for power system EMC measurements.
更多
查看译文
关键词
Sensor systems,Power system measurements,Electromagnetic compatibility,Power measurement,Magnetic sensors,Power system modeling,Sensor phenomena and characterization,Power system analysis computing,Electromagnetic measurements,Signal processing algorithms