Optimum Global Failure Prediction Model of Steam Generator Tube With Two Parallel Axial Through-Wall Cracks

JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME(2005)

引用 4|浏览9
暂无评分
摘要
The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In the previous study (Moon et al. (2002)), a total number of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Three previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a crack opening displacement (COD) base model was selected as an optimum model.
更多
查看译文
关键词
steam generator tube,plastic collapse load,interaction effect,failure prediction model