Electromagnetic field measurements a millimeter wave linear accelerator

Microwave Theory and Techniques, IEEE Transactions(1996)

引用 15|浏览9
暂无评分
摘要
Perturbational field strength measurements suitable for use on a proposed 120-GHz 50-MeV electron linear accelerator are described. The measurements are used to determine the R/Q of the device, where R is the shunt impedance. The perturbation is achieved by the use of hollow metallic cylinders with diameters ranging from 25 to 127 μm which are approximately 500 μm long. The cylinders were fabricated by sputtering aluminum through a shadow mask onto silica optical fibers as well as nylon surgical thread. The perturbational “form factors” for such a geometry are experimentally determined using a pillbox cavity. The measured values for the form factors are compared to theoretical estimations, which result in simple analytical expressions. The measured form factors are also compared to values calculated from a finite difference model of the perturbing object. The R/Q for various accelerating modes is measured on a 12-GHz model of the 120-GHz structure. Results are compared to predictions from a finite difference model of the accelerating structure
更多
查看译文
关键词
Q-factor,electromagnetic fields,electron accelerators,finite difference methods,linear accelerators,millimetre wave devices,millimetre wave measurement,perturbation theory,120 GHz,50 MeV,aluminium sputtering,electromagnetic field,finite difference model,hollow metallic cylinder,millimeter wave electron linear accelerator,nylon surgical thread,perturbational form factor,pillbox cavity,quality factor,shadow mask,shunt impedance,silica optical fiber