Objective Inertial measurement units (IMUs) offer a method for assessing gait beyond the confines of a laboratory. Signal noise and calibration errors pose significant obstacles to accurately estimating joint angles, particularly during dynamic activities such as running. Advancements in dynamic optimisation tools could enable a more comprehensive analysis with fewer sensors and/or low-quality data. The objective of this study was to compare two IMU-based modelling approaches (inverse kinematics and optimal control simulations) with optical marker-based motion capture in reconstructing running gait kinematics. Methods Six participants performed treadmill running at three speeds whilst marker trajectories and IMU signals were collected concurrently. The subject-specific biomechanical model consisted of a 3D representation of the lower body and torso, with contact spheres added to simulate ground contact in the optimal control simulations. The objective of the optimal control simulations was to track the accelerations, angular velocities, and orientations of eight sensors with simulated signals from the model sensors. Additional constraints were enforced, reflecting physiological and biomechanical principles and targeting dynamic consistency. The objective of the IMU-based inverse kinematics was to minimize the difference between the input and simulated sensor orientations. The joint kinematics derived from both methods were compared against optical marker-based motion capture across a range of running speeds, evaluating the absolute and normalized root mean square errors. Results Compared with motion-capture joint angles, optimal control simulations resulted in lower absolute errors (RMSE 8° ± 1) that were consistent across all speeds. IMU-based inverse kinematics exhibited greater differences with motion capture (RMSE 12° ± 1), which was more significant at faster speeds. The largest absolute inaccuracies were observed in the sagittal angles when not normalizing for the joint range of motion. The computational times for the optimal control were 46 ± 60 min, whereas they were 19.3 ± 3.7 s for the IMU-based inverse kinematics. Conclusions Compared with traditional IMU-based inverse kinematics, the optimal control approach provides a more comparative representation of joint kinematics from optical motion capture. This method can mitigate errors associated with closely tracking IMU noise and drift, and it offers a dynamic analysis that considers the underlying forces and torques producing movement. However, these advantages come at the expense of challenges in parameter selection and computational cost. Significance These findings highlight the potential of using IMUs with optimal control methods to provide a comprehensive understanding of gait dynamics across diverse applications. IMU-based inverse kinematics remains a viable option for faster computation and when model fidelity is less of a concern.
More
Translated text
Key words
Optimal control,Gait,Inertial measurement unit,Running,Biomechanics,Wearable sensor
求助PDF
上传PDF
Bibtex
收藏
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined