Implementation of Optically Simulated Luminescent Dosimeter for Quality Control of Gamma Ray Dose of an Accelerator-Based Neutron Source
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS(2024)
Osaka Med & Pharmaceut Univ
Abstract
BackgroundNeutron beams utilized for performing BNCT are composed of a mixture of neutrons and gamma rays. Although much of the dose delivered to the cancer cells comes from the high LET particles produced by the boron neutron capture reaction, the dose delivered to the healthy tissues from unwanted gamma rays cannot be ignored. With the increase in the number of accelerators for BNCT, a detector system that is capable of measuring gamma ray dose in a mixed neutron/gamma irradiation field is crucial. Currently, BeO TLDs encased in quartz glass are used to measure gamma ray dose in a BNCT irradiation field. However, this type of TLD is no longer commercially available. A replacement dosimetry system is required to perform the recommended ongoing quality assurance of gamma ray measurement for a clinical BNCT system.PurposeThe purpose of this study is to evaluate the characteristics of a BeO OSLD detector system under a mixed neutron and gamma ray irradiation field and to assess the suitability of the system for routine quality assurance measurements of an accelerator-based BNCT facility.MethodsThe myOSLD system by RadPro International GmbH was evaluated using the accelerator-based neutron source designed for clinical BNCT (NeuCure BNCT system). The readout constancy, linearity, dose rate effect, and fading effect of the OSLD were evaluated. Free-in-air and water phantom measurements were performed and compared with the TLD results and Monte Carlo simulation results. The PHITS Monte Carlo code was used for this study.ResultsThe readout constancy was found to be stable over a month-long period and similar to the TLD results. The OSLD readout signal was found to be linear, with a high coefficient of determination (R2 >= 0.999) up to a proton charge of 3.6 C. There was no significant signal fading or dose rate dependency. The central axis depth dose and off-axis dose profile measurements agreed with both the TLD and Monte Carlo simulation results, within one standard deviation.ConclusionThe myOSLD system was characterized using an accelerator system designed for clinical BNCT. The experimental measurements confirmed the OSLD achieved similar, if not superior to, the currently utilized dosimetry system for routine QA of an accelerator-based BNCT system. The OSLD system would be a suitable replacement for the current TLD system for performing routine QA of gamma ray dose measurement in a BNCT irradiation field.
MoreTranslated text
Key words
accelerator neutron source,BNCT,Monte Carlo simulation,OSLD,QA
上传PDF
View via Publisher
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
- Pretraining has recently greatly promoted the development of natural language processing (NLP)
- We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
- We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
- The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
- Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined