MRI-based Neuropathy Score Reporting And Data System (NS-RADS): multi-institutional wider-experience usability study of peripheral neuropathy conditions among 32 radiology readers

Avneesh Chhabra,Flavio Duarte Silva,Bayan Mogharrabi,Mina Guirguis,Oganes Ashikyan, Michael Rasper, Eunhae Park,Sven S. Walter,Monica Umpierrez,Parham Pezeshk,Peter C. Thurlow, Akshaya Jagadale, Gitanjali Bajaj,Aparna Komarraju,Jim S Wu, Antonio Aguilera,Fabiano Nassar Cardoso, Felipe Souza, SubbaRao Chaganti,Neha Antil,Wilfred Manzano, Alexander Stebner, Jochen Evers,Matthew Petterson, Thomas Geisbush, Chad Downing, Diana Christensen, Elizabeth Horneber, Jun Man Kim,Rangarajan Purushothaman, Shilpa Mohanan,Surbhi Raichandani,George Vilanilam, Clementina Cabrera,John Manov, Sean Maloney,Swati D. Deshmukh,Amelie M. Lutz,Jan Fritz,Gustav Andreisek,Majid Chalian,Philip K. Wong,Tarun Pandey,Ty Subhawong,Yin Xi

European Radiology(2024)

引用 0|浏览7
暂无评分
摘要
Objective To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system. Methods This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger’s kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings. Results Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1–88.8%) and trainees, 86.6% (95% CI 85.2–87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) ( p = 0.036). Conclusion Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system. Clinical relevance statement The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists. Key Points • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).
更多
查看译文
关键词
Peripheral neuropathy,Magnetic resonance imaging,Peripheral nerve injury,Entrapment neuropathies,Peripheral nerve sheath tumor
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要