Effect of sensor number and location on accelerometry-based vertical ground reaction force estimation during walking

medRxiv (Cold Spring Harbor Laboratory)(2023)

引用 0|浏览7
暂无评分
摘要
Knee osteoarthritis is a major cause of global disability and is a major cost for the healthcare system. Lower extremity loading is a determinant of knee osteoarthritis onset and progression; however, technology that assists rehabilitative clinicians in optimizing key metrics of lower extremity loading is significantly limited. The peak vertical component of the ground reaction force (vGRF) in the first 50% of stance is highly associated with biological and patient-reported outcomes linked to knee osteoarthritis symptoms. Monitoring and maintaining typical vGRF profiles may support healthy gait biomechanics and joint tissue loading to prevent the onset and progression of knee osteoarthritis. Yet, the optimal number of sensors and sensor placements for predicting accurate vGRF from accelerometry remains unknown. Our goals were to: 1) determine how many sensors and what sensor locations yielded the most accurate vGRF loading peak estimates during walking; and 2) characterize how prescribing different loading conditions affected vGRF loading peak estimates. We asked 20 young adult participants to wear 5 accelerometers on their waist, shanks, and feet and walk on a force-instrumented treadmill during control and targeted biofeedback conditions prompting 5% underloading and overloading vGRFs. We trained and tested machine learning models to estimate vGRF from the various sensor accelerometer inputs and identified which combinations were most accurate. We found that a neural network using one accelerometer at the waist yielded the most accurate loading peak vGRF estimates during walking, with errors around 4.3% body weight. The waist-only configuration was able to distinguish between control and overloading conditions prescribed using biofeedback, matching measured vGRF outcomes. Including foot or shank acceleration signals in the model reduced accuracy, particularly for the overloading condition. Our results suggest that a system designed to monitor changes in walking vGRF or to deploy targeted biofeedback may only need a single accelerometer located at the waist. ### Competing Interest Statement Jason Franz and Brian Pietrosimone are founders and Chief Technology Officer and President, respectively, of VETTA Solutions, Inc, a start-up company with prospective product solutions in the areas of wearable sensor solutions for musculoskeletal health applications. The conceptualization of this study and all data collections and analyses were completed prior to the incorporation date of the company. ### Funding Statement J.F. and B.P. recieved funding from the UNC Chapel Hill Eshelman Institute for Innovation (https://unceii.org/ideas/) for this study. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. ### Author Declarations I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained. Yes The details of the IRB/oversight body that provided approval or exemption for the research described are given below: University of North Carolina at Chapel Hill Institutional Review Board (Study # 21-1693). I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable. Yes The data that support the findings of this study are publicly available from DBHub.io with the identifier(s) [https://dbhub.io/peruvianox/Pilot1_steps.db].
更多
查看译文
关键词
sensor number,ground,accelerometry-based
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要