WeChat Mini Program
Old Version Features

Technical Note: First Implementation of a One-Stop Solution of Radiotherapy with Full-Workflow Automation Based on CT-linac Combination

MEDICAL PHYSICS(2023)

Fudan Univ

Cited 2|Views33
Abstract
BackgroundRadiotherapy initiation is a laborious and time-consuming process that involves multiple steps and units. Workflow automation is in demand to improve the work efficiency and patient experience. PurposeThe purposes of this study are to describe the technical characteristics and clinical performance of an AI-powered one-stop radiotherapy workflow for initial treatment based on CT-linac combination, and provide insight into the behavior of full-workflow automation in radiotherapy. MethodsBased on a CT-integrated linear accelerator and AI model implementation, the so-called "All-in-One" workflow incorporates routine procedures from simulation, autosegmentation, autoplanning, image guidance, beam delivery, and in vivo quality assurance (QA) into one scheme, while the patient is on the treatment couch. Clinical outcomes of the new workflow were evaluated for 10 enrolled patients with rectal cancer. ResultsFor the enrolled patients, manual modifications of the autosegmented target volumes were necessary. The Dice similarity coefficient and 95% Hausdorff distance before and after the modifications were 0.892 +/- 0.061 and 18.2 +/- 13.0 mm, respectively. The autosegmented normal tissues and automatic plans were clinically acceptable without any modifications or reoptimization. The pretreatment IGRT corrections were within 2 mm in all directions, and the EPID-based in vivo QA showed gamma passing rate of above 97% (3%/3 mm/10% threshold) at all the checkpoints, better than the results of rectal patients who followed a routine workflow. The duration of the whole process was 23.2 +/- 3.5 minutes for the enrolled patients, depending mostly on the time required for manual modification and plan evaluation. ConclusionThe All-in-One workflow enables full-process automation of radiotherapy via seamless procedure integration. Compared to the routine workflow, the one-stop solution shortens the time scale it takes to ready the first treatment from days to minutes, significantly improving the patient experience and the workflow efficiency, and it also shows potential to facilitate clinical application of online adaptive replanning.
More
Translated text
Key words
full-workflow automation,one-stop radiotherapy,online adaptive replanning
求助PDF
上传PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined