Electrostatic-lenses position-sensitive TOF MCP detector for beam diagnostics and new scheme for mass measurements at HIAF

Nuclear Science and Techniques(2019)

引用 11|浏览15
暂无评分
摘要
foil–microchannel plate (MCP) detector, which uses electrostatic lenses and possesses both good position and timing resolutions, has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China. Characterized by low energy loss and good performances of timing and position measurements, it would be located at focal planes in fragment separator HFRS for position monitoring, beam turning, Bρ measurement, and trajectory reconstruction. Moreover, it will benefit the building-up of a magnetic-rigidity–energy-loss–time-of-flight ( Bρ-ΔE-TOF ) method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis. Most importantly, the detector can be utilized for in-ring TOF and position measurements, beam-line TOF measurements at two achromatic foci, and position measurements at a dispersive focus of HFRS, thus making it possible to use two complementary mass measurement methods [isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight ( Bρ-TOF ) at the beam-line HFRS] in one single experimental run.
更多
查看译文
关键词
Microchannel plate, Electrostatic lenses, Detector, Position-sensitive, Time-of-flight, Mass measurements, HIAF
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要