Synchronous Rectification for a Two-Transformer Active-Clamp Forward-Flyback Converter to Remove Voltage Spikes

Seokwon Kim, Hanhim Sung, Dae-Woo Lee, Tae-Jong Ha, Jun-Young Lee,Jong-Won Shin

2024 IEEE Applied Power Electronics Conference and Exposition (APEC)(2024)

引用 0|浏览0
暂无评分
摘要
The paper proposes a new synchronous rectification (SR) for a two-transformer active-clamp forward-flyback converter (ACFF). The proposed method synchronizes the overlapped turn-on interval of SR field effect transistors (FETs) to the falling edge of the primary-side gate signals. The proposed method eliminates the voltage spike of SR FETs in discontinuous conduction mode. The interval of the overlap is fixed regardless of the input voltage or output power of the converter. This requires no additional voltage or current sensing and saves the computational resources of microcontroller unit. The performance of the proposed SR is verified by an 800 V-14 V 100-W prototype two-transformer ACFF.
更多
查看译文
关键词
synchronous rectification,forward-flyback converter,voltage spike
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要