Experimental and numerical investigations of multi-layered ship engine room bulkhead insulation thermal performance under fire conditions

Thanh-Nhut Pham, Quoc Tien Le,Quang Thang Do

CURVED AND LAYERED STRUCTURES(2024)

引用 0|浏览0
暂无评分
摘要
The thermal insulation layer of the ship's engine room bulkhead is typically constructed from multiple layers of mineral wool. This layer is designed to keep the temperature on the surface of the bulkhead below 140(degrees)C in case of a fire. However, measuring the inner and external temperatures of each wall panel bulkhead type during a fire can be difficult. To address this issue, this study was conducted to evaluate the multilayer heat transfer capability of the bulkhead insulation in the event of an engine room fire. The study used heat transfer theory, experimental models, and numerical analysis to assess nine bulkhead insulation specimens. These specimens were fabricated from three original specimens and included a 10-30 mm air layer (W-75, W-50, and W-25). The results showed that all improved specimens had better thermal insulation than the originals. Among them, the improved specimens derived from the W-25 specimen exhibited the most significant temperature reduction compared to those derived from the W-75 and W-50 specimens. The results demonstrated a slight difference between the three methodologies, indicating a high level of reliability in the research findings.
更多
查看译文
关键词
heat transfer,insulation,engine room wall,fire protection,multi-layer structure