Reducing Airway Occlusion Time Without Losing Accuracy to Predict Successful Mechanical Ventilator Liberation During the Measurement of the Timed Inspiratory Effort Index

Raphaela Cristinne Carvalho Cordeiro,Leonardo Cordeiro de Souza,Jocemir Ronaldo Lugon

Respiratory Care(2024)

引用 0|浏览0
暂无评分
摘要
BACKGROUND:In 2013, a new predictor of successful mechanical ventilation liberation named timed inspiratory effort (TIE) index was devised with the normalization of the maximum inspiratory pressure (obtained within 60 s of unidirectional airway occlusion) with the time at which the value was reached. The aim of this study was to verify whether the presence of a sequence of a certain number of inspiratory effort values between 30-60 s > 1.0 cm H2O/s could predict weaning success in a performance comparable to the TIE index. METHODS:This was a retrospective observational study using 4 databases of previous studies on the TIE index. All patients receiving mechanical ventilation for ≤ 24 h were eligible. Liberation from mechanical ventilation-extubation decisions was made based on performance with spontaneous breathing trials. P < .05 was considered significant. The performance of the TIE index was evaluated by calculating the area under the receiver operating characteristics (AUROC) curve. RESULTS:From 349 eligible patients, 165 subjects were selected for analysis. The AUROC for the TIE index in the studied sample was 0.92 (95% CI 0.87-0.97, P < .001). A sequence of ≤ 4 inspiratory efforts > 1.0 cm H2O/s was found in 51.5% of the subjects, with successful ventilatory liberation occurring in 95.3%. The highest specificity values belonged to the sequence of ≤ 4 and ≤ 5 inspiratory efforts > 1.0 cm H2O/s; the highest positive predictive value and positive likelihood ratio belonged to the sequence of ≤ 4 inspiratory efforts > 1.0 cm H2O/s. The mean time that could have been spared if the procedure were interrupted after the first sequence of 4 inspiratory efforts > 1.0 cm H2O/s was 23 ± 3 s. CONCLUSIONS:The presence of a sequence of ≤ 4 inspiratory efforts > 1.0 cm H2O/s during the TIE index measurement was a reliable predictor of weaning success, which could allow timely interruption of the procedure and entail a substantial reduction in airway occlusion time.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要