Experimental study of smoke characteristics in a double-deck tunnel with multiple point extraction using a branch pipe

Zhan Wang,Zhi Tang,Zheng Fang, Zhiming He, Tao Yang, Min Zhou, Enshi Wang, Yinhang Xu

Fire Safety Journal(2024)

引用 0|浏览0
暂无评分
摘要
A reduced scale 1:8 double-deck tunnel model was built to study smoke control performance of a semi-transverse ventilation system using a branch pipe to connect the lower deck tunnel to the upper smoke duct. 41 experiments were conducted to analyze the effects of different activation modes of smoke vents, heat release rate (HRR), and exhaust smoke rates on smoke spread distance. An optimum smoke control mode was found by activating two vents near the fire source when the heat release rate was 44.19 kW (8 MW at full scale) and the fan's extraction rate was 0.66 m3/s (120 m3/s at full scale) using a branch pipe. Results showed that as HRRs rise, the smoke spread distance first increases and then remains constant. The ratio of the smoke spreading distance on the upstream side of the fire to the total smoke spreading distance was 0.4 in this experimental setup. Furthermore, fire smoke spread characteristics were quantified for a typical ventilation design.
更多
查看译文
关键词
Tunnel fire,Double-deck tunnel,Semi-transverse ventilation,Branch pipe,Fire smoke,Smoke exhaust