Assessment of Bioaerosol Contamination (bacteria and fungi) in Operating Rooms of The Largest Educational Hospital in Shiraz, Iran

Iranian Journal of Health, Safety and Environment(2024)

引用 0|浏览0
暂无评分
摘要
There is a concern about exposure to bio-aerosols due to their harmful health effects. Bio-aerosols in surgery environment can potentially cause infection in susceptible and unsusceptible patients. The present study aimed to evaluate bacterial and fungal densities and species in surgery rooms in an educational hospital in Shiraz. A total of 168 sam¬ples were collected. Active sampling was done by using a single-stage Anderson sampler on plates including blood agar and sabouraud dextrose agar for 10 minutes for bacteria and fungi, respectively. The mean densities of fungi and bacteria were respectively 233.23±2.024 and 232.6±1.383 CFU/m3 before sterilization compared to 233.01±2.041 and 233.57±1.324 CFU/m3 after sterilization of the surgery rooms. No significant difference was observed between the densities of bacteria and fungi before and after sterilization in all surgery rooms (P>0.05). However, it was a significant difference between the total densities of bio-aerosols after sterilization compared to the suggested value. The density of bio-aerosols was greater than 30 CFU/m3 (P
更多
查看译文
关键词
air pollution,bio-aerosols,bacteria,fungi,operating room