Cardiopulmonary Exercise Testing after Surgical Repair of Tetralogy of Fallot-Does Modality Matter?

Benedetta Leonardi,Fabrizio Sollazzo, Federica Gentili,Massimiliano Bianco, Elettra Pomiato,Stefani Silva Kikina, Rachel Maya Wald,Vincenzo Palmieri, Aurelio Secinaro,Giulio Calcagni, Gianfranco Butera,Ugo Giordano, Giulia Cafiero,Fabrizio Drago

JOURNAL OF CLINICAL MEDICINE(2024)

引用 0|浏览0
暂无评分
摘要
Background: Despite a successful repair of tetralogy of Fallot (rToF) in childhood, residual lesions are common and can contribute to impaired exercise capacity. Although both cycle ergometer and treadmill protocols are often used interchangeably these approaches have not been directly compared. In this study we examined cardiopulmonary exercise test (CPET) measurements in rToF. Methods: Inclusion criteria were clinically stable rToF patients able to perform a cardiac magnetic resonance imaging (CMR) and two CPET studies, one on the treadmill (incremental Bruce protocol) and one on the cycle ergometer (ramped protocol), within 12 months. Demographic, surgical and clinical data; functional class; QRS duration; CMR measures; CPET data and international physical activity questionnaire (IPAQ) scores of patients were collected. Results: Fifty-seven patients were enrolled (53% male, 20.5 +/- 7.8 years at CPET). CMR measurements included a right ventricle (RV) end-diastolic volume index of 119 +/- 22 mL/m(2), a RV ejection fraction (EF) of 55 +/- 6% and a left ventricular (LV) EF of 56 +/- 5%. Peak oxygen consumption (VO2)/Kg (25.5 +/- 5.5 vs. 31.7 +/- 6.9; p < 0.0001), VO2 at anaerobic threshold (AT) (15.3 +/- 3.9 vs. 22.0 +/- 4.5; p < 0.0001), peak O-2 pulse (10.6 +/- 3.0 vs. 12.1 +/- 3.4; p = 0.0061) and oxygen uptake efficiency slope (OUES) (1932.2 +/- 623.6 vs. 2292.0 +/- 639.4; p < 0.001) were significantly lower on the cycle ergometer compared with the treadmill, differently from ventilatory efficiency (VE/VCO2) max which was significantly higher on the cycle ergometer (32.2 +/- 4.5 vs. 30.4 +/- 5.4; p < 0.001). Only the VE/VCO2 slope at the respiratory compensation point (RCP) was similar between the two methodologies (p = 0.150). Conclusions: The majority of CPET measurements differed according to the modality of testing, with the exception being the VE/VCO2 slope at RCP. Our data suggest that CPET parameters should be interpreted according to test type; however, these findings should be validated in larger populations and in a variety of institutions.
更多
查看译文
关键词
cardiopulmonary exercise testing,congenital heart disease,cycle ergometer,treadmill,protocol selection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要