Ductility-related seismic modification factor for CLT shear-wall and glulam moment-resisting frame dual system

CANADIAN JOURNAL OF CIVIL ENGINEERING(2024)

引用 0|浏览0
暂无评分
摘要
The cross-laminated timber (CLT) shear-wall and glulam moment-resisting frame (CLTW-GMRF) dual system is a recently completed research prepared for the British Columbia (BC) Forestry Innovation Investment Ltd. With the introduction of new structural systems, the need to update existing building code becomes evident. Accordingly, this study evaluates the ductility-related force modification factor (Rd) of the CLTW-GMRF system for the National Building Code of Canada, utilizing the FEMA P-695 procedure. In two performance groups, 16 archetype buildings are designed considering different building storey heights, CLT shear-wall locations, and wall-frame moment proportions. Numerical model of the systems is developed in OpenSees and incremental dynamic analyses are conducted using 30 bi-directional ground motion records that represent the seismicity of Vancouver, BC, Canada. Collapse margin ratios are calculated to assess the adequacy of the trial Rd factors. The research determined that with an over-strength factor of 1.5, an Rd of 3 is found to be acceptable for the system.
更多
查看译文
关键词
cross-laminated timber,dual system,ductility-related seismic modification factor,glued-laminated timber,timber moment-resisting frame
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper